Normalization of Data
CPCB Guidelines
CPCB 1ST revised Guidelines on 14 June 2018 days
-
Normalization of Emission Values
-
Moisture Measurement
-
O2 or CO Measurement
Need to Measure Pressure, Temperature & Flow
-
TPF-100 integrated temperature, pressure and flow rate detector For real-time monitoring
-
With all-in-one design and structure, TFP-100 in a single rugged enclosure to strengthen measuring efficiency and reduce openings.
Temperature Transmitter
-
Measuring principle: Temperature sensor
-
Material: WZP platinum resistance
-
Measuring range: (0~400)℃ (optional as per actual operating conditions)
-
Measuring accuracy: ±0.5%
-
Input voltage: 24V DC
-
Output current:: Two-wire system (4-20) mA
-
Insertion length: (200-2000) mm or customized insertion length
-
Others: The temperature transmitter sleeve enclosure is coated with anticorrosion materials (polytetrafluoroethylene) and a mounting base is provided.
Pressure Transmitter
-
Measuring principle: Pressure sensor
-
Measuring range: (-10~10) Kpa (optional as per actual operating conditions)
-
Measuring accuracy: ±0.5%
-
Input voltage: 24V DC
-
Output current:: Two-wire system (4-20) mA
Flow Rate Transmitter
-
Measuring principle: Pitot tube plus differential pressure transmitter (Pitot tube + differential pressure transmitter)
-
Measuring range: (0~10) m/s to (0~80) m/s, optional as per actual operating conditions.
-
Measuring accuracy: ≤±5%F.S.
-
Input voltage: 24V DC
-
Output current:: Two-wire system (4-20) mA
-
Insertion length: (200-2000) mm or customized length
Others
-
Others: The surface is coated with special anticorrosion materials
-
(polytetrafluoroethylene); mounting flange and bolt spacer are provided.
Back blowing system:
-
Including SMC solenoid valve, gas jet and tee, etc.
-
Input voltage: 220V AC